In order to ensure the authenticity,accuracy and completeness of the data from automatic water quality monitoring station in Danjiangkou Reservoir Area,in terms of data collection and transmission,we standardize the sampling and data transmission requirements,and improve the upload of key parameters and process log information. In terms of personnel management,data auditors must pass the technical training and assessment organized by competent department,and have relevant capabilities such as comprehensive data analysis and quality management. In the data review process,a strict review process design is carried out for the monitoring data. The monitoring data review of the water station is carried out via online platform,to ensure the whole review process are recorded. In terms of quality control management,the water station has established multi-level quality control measures (including daily/weekly/monthly quality control and blind sample assessment) and a multi-dimensional quality control system throughout the entire water station operation. In terms of data continuity,manual supplementary testing is completed in time according to diff erent outage conditions. Meanwhile,the national monitoring technical index system provides technical basis for ensuring the authenticity and accuracy of monitoring data. Through all the above-mentioned measures,it can ensure that the automatic monitoring data is true,accurate and complete.